Core identification
Colour
Colour outer sheath
Orange
Diameter conductor (mm)
0.58
Conductor material
Copper
Screen over stranding element
Foil
Screen over stranding
Braiding
Material outer sheath
Polyolefin
Characteristic impedance (Ohm)
100
Conductor category
Class 1 = solid
Armouring/reinforcement
None
Permitted cable outer temperature during assembling/handling (°C)
0 - 50
Permitted cable outer temperature after assembling without vibration (°C)
-20 - 60
Number of stranding elements
4
Suitable for underground installation
No
Halogen free according to EN IEC 60754-2
Yes
Insulation integrity according to IEC 60331
No
Low smoke according to EN IEC 61034-2
No
Outer diameter approximate (mm)
7.5
With rodent protection
false
Low smoke (according to EN 61034-2)
No
Halogen free according to EN 60754-1/2
Yes
Oil resistant (according to IEC 60811-404)
No
Longitudinal water blocking cable
false
Radial water blocking cable
false
Reaction-to-fire according to EN 13501-6: Class
Cca
Reaction-to-fire according to EN 13501-6: Smoke production
s1
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
d1
Reaction-to-fire according to EN 13501-6: Acidity
a1
Min. permitted bending radius, moving application with forced guidance (mm)
0
Min. permitted bending radius, moving application/free movement (mm)
0
Min. permitted bending radius, stationary application/permanent installation (mm)
30
Specification material outer sheath
Other
Core identification according to HD 308 S2
No
Suitable as telephone cable
Yes
Suitable as computer data cable
Yes
Suitable as signalling cable
Yes
Certified for shipboard application
No
Max. tensile strength during installation (kN)
0.18
Approved type of underground installation
Underground installation tube